What We Do

Calibration Services

From single transmitters to full facility gas detection systems, we ensure your equipment performs within manufacturer spec and regulatory requirements.

FIELD CAL

On-Site Calibration

We come to your facility and calibrate fixed-mounted detectors in place. Zero and span calibration performed with certified reference gas — no downtime for shipping.

BENCH CAL

Bench Calibration

Send us your transmitters for thorough zero/span adjustment, sensor health check, and full documentation. Typical 3–5 day turnaround with a calibration certificate.

SENSOR SVC

Sensor Replacement

Electrochemical CO sensors degrade over time. We supply and install OEM-compatible replacement sensors, recalibrate, and verify operation before return.

COMPLIANCE

Compliance Reporting

Receive NIST-traceable calibration certificates, pass/fail records, and maintenance logs formatted for OSHA, insurance, and safety audits.

CONTRACT

Service Agreements

Annual or semi-annual contracts for facilities with multiple units. We schedule visits automatically — you stay compliant without having to track it yourself.

EMERGENCY

Alarm Response Cal

After a CO alarm event, sensors may be overexposed and inaccurate. We offer priority re-calibration and sensor integrity assessment to restore reliable operation.

The Calibration Process

Every calibration follows a defined, documented procedure. Here's what happens from the moment you contact us.

01

Request & Assessment

Tell us how many units you have, their model numbers, and your site location. We'll confirm the calibration gas required (e.g., 50 ppm CO balance N₂ for Vulcain Q1-CO units) and provide a quote within one business day.

02

Zero Calibration

Clean air (or N₂) is applied to the sensor to establish a stable baseline. The zero potentiometer is adjusted until the output reads 0 ppm. Unit is allowed to fully stabilize before proceeding.

03

Span Calibration

Certified reference span gas at a known concentration is applied. The span potentiometer is adjusted until the display and analog output match the reference value within ±2% of full scale. Gas is flowed for a minimum of one minute before adjustment.

04

Alarm & Relay Verification

We confirm that alarm thresholds, relay outputs, and LED indicators activate correctly at the programmed set-points. Time delays are verified against the original specification.

05

Documentation & Certificate

A calibration certificate is issued with as-found and as-left readings, reference gas certificate numbers, technician signature, and the next recommended calibration date. All records retained for 5 years.

Equipment Expertise

What We Calibrate

From parking-garage CO transmitters to wireless industrial gas monitors, we calibrate fixed-point detection equipment across all major platforms.

Emerson / Rosemount

Rosemount 928 Series

The 928 Wireless Gas Monitor uses a smart 628-series sensor module that stores its own calibration data. We perform sensor-level zero and span calibration via Field Communicator, and verify bump test response for H₂S, CO, and O₂ depletion variants.

  • Rosemount 928 Wireless Gas Monitor
  • Rosemount 628E / 628EC Toxic Gas Sensors
  • H₂S · CO · O₂ Depletion · Combustible LEL
  • WirelessHART integration verification
Endress+Hauser

E+H Gas Transmitters

Endress+Hauser process analyzers and fixed transmitters require meticulous calibration of both the sensor cell and the 4–20 mA output loop. We follow documented E+H procedures and issue NIST-traceable certificates accepted for IEC 61511 safety documentation.

  • Liquiline CM442 / CM444 Multi-Parameter
  • SS2100a TDLAS Gas Analyzers (H₂O, H₂S, CO₂)
  • Transducer / 4–20 mA output loop calibration
  • Heartbeat Technology verification
Yokogawa

Yokogawa Process Analyzers

Yokogawa's gas measurement lineup spans in-situ zirconia oxygen probes to gas density analyzers. We calibrate both zero/span and converter output, and can perform the three calibration modes supported by the GD402 platform: automatic, semi-automatic, and one-touch manual.

  • ZR22S / ZR402G Zirconia O₂ Analyzer
  • GD402 / GD40 Gas Density Analyzer
  • TDLS8000 / TDLS8220 Laser Spectrometer
  • ZR802S Combustion O₂ (explosion-proof)
Also Serviced

Other Platforms

If it has a sensor, a zero pot, and a span pot, we can calibrate it. Contact us with your model number if you don't see it listed.

  • MSA ULTIMA XE / Chillgard Series
  • Honeywell Analytics XCD / OLCT 100
  • General Monitors S4000 / FL4000
  • Macurco / Aerionics CD-6 / TX-6
  • Draeger Polytron 7000 Series
  • Sierra Monitor / Sensidyne SensAlert
Why Choose Us

Built on Reliability

Traceable Standards

All reference gases carry NIST-traceable certificates. Your calibration documentation stands up to any audit.

Manufacturer Procedure

We follow the published Vulcain VA201T/M calibration procedure exactly — no shortcuts, no improvisation.

Twice-a-Year Reminder

CO sensor manufacturers recommend calibration every six months. We track your schedule and remind you automatically.

Sensor Integrity Check

If a sensor can't be zeroed or spanned correctly, we tell you — and explain your replacement options before charging you.

Request a Calibration

Tell us about your equipment and we'll get back to you within one business day with availability and pricing.